Tuesday, April 21, 2020

Effect of Labor Augmentation Using Oxytocin on Neonatal Outcome, A Case Control Study - Juniper Publishers

Gynecology and Women’s Health - Juniper Publishers



Abstract

Aims: To re-evaluate whether augmentation of labor with oxytocin in dysfunctional labor, has a hazardous effect on neonatal Apgar scores, umbilical cord pH or blood gases
Materials and Methods: Prospective study where one hundred and fifty-three (153) patients in spontaneous labor were involved in the analysis. Seventy-nine patients (Group I) with hypo-contractile uterine activity were managed by low-dose oxytocin protocol for labor augmentation, while 74 patients (Group II) were not managed by augmentation of labor using oxytocin. Primary outcomes were Apgar score at 5th minutes of birth and umbilical artery pH, while secondary outcomes were Apgar score at 1st minute, arterial pO2, pCO2 and base deficit of all neonates.
Result: In this study, there was no significant difference between cases and controls regarding; Apgar score at 1st minute, Apgar score at 5th minute, mean umbilical artery pCO2 and pO2 while mean umbilical artery pH was significantly lower and umbilical artery base deficit was significantly higher in the case group compared to the control group. Moreover, umbilical artery pH was negatively correlated to duration of oxytocin administration.
Conclusion: Oxytocin use to augment labor, although affects umbilical cord blood gases, doesn’t significantly affect neonatal outcome if used in a proper dose to produce efficient uterine contractions

Keywords: Apgar score Augmentation Cord gases Oxytocin


Introduction

Approximately 20 percent of labors involve either protraction or arrest disorders [1]. The active management of labor was introduced during the 1960’s at the National Maternity Hospital in Dublin, Ireland to augment labor in nulliparous women. Proponents of this approach have suggested that it also safely reduces the number of Cesarean deliveries [2]. Oxytocin increases frequency of contractions, causes initial transient increase in the base tone (incomplete relaxation) and increases the amplitude and duration of phasic contractions [3]. During parturition, prolonged tonic contractions might be harmful for fetuses because an increase of the intrauterine pressure would disturb the feto-maternal circulation and may occlude blood vessels within the myometrium [4]. Utero-placental hypo-perfusion is the major cause of both respiratory and metabolic acidemia, with progression from the former to the latter over time if decreased utero-placental blood flow is not corrected [5], hence various studies were designed to study the safety of using oxytocin infusion during the course of labor on neonatal clinical and acid-base condition at delivery and the likelihood of causing perinatal asphyxia.


Materials and Methods

The study was conducted in Ain Shams University Maternity Hospital and El-Sahel Teaching Hospital in Cairo, Egypt, which are two big tertiary hospitals, from January till October 2010, where 180 patients in spontaneous labor were initially enrolled in this case-control study after informed consent and approval of the study protocol by the institute ethics committee. Ninety patients who fulfilled the selection criteria, were diagnosed as primary failure of progression in labor due to hypo-contractile uterine activity and managed by augmentation of labor using low-dose oxytocin (Syntocinon® 10 IU/ml concentrate for solution for infusion) (Group I). Another group of ninety patients also fulfilled the selection criteria but were not managed by augmentation of labor using oxytocin (Group II). Participants were all aged between 18 and 45 years old, free of medical disorders, planned for vaginal delivery having singleton pregnancy at full term admitted at 3-5cm cervical dilatation with vertex presentation of estimated fetal weight between 2500 to 4000 grams with average amniotic fluid volume and morphologically normal fetus, with no evidence of fetal distress or placental insufficiency and with uncomplicated pregnancy as detected by antenatal course.
All neonates were assessed using Apgar score at 1st and 5th minutes by same observer and umbilical cord blood samples were obtained from all neonates where a segment of 10-20cm of umbilical cord was doubly clamped and excised immediately after delivery then 1-2ml blood withdrawn in a heparinized syringe; one from the artery and the other from the vein then kept in ice and transported to the laboratory within 60 minutes and analyzed using blood analyzer (i-STAT300F, Abbott Point of Care Inc., USA).

Prior to start of the study, all participants were assessed to confirm eligibility then were consistently managed according to the local institutional intra-partum protocol and received proper monitoring and supportive care. Normal FHR pattern and assessment of uterine activity were confirmed using Cardiotocography (CTG) for 30 minutes before starting interventions. Intermittent auscultation was used in low-risk women while continuous electronic fetal monitoring was used for the high-risk cases. Vaginal examination was performed two hourlies, unless clinically indicated, to monitor progress of labor. Artificial rupture of fetal membranes (ROM) was considered, in women with intact membranes, if there was poor progress of labor (cervical dilatation <1cm/hour) with inefficient uterine contractions 2hours after ROM, the woman was assigned to Group I, receiving low-dose oxytocin protocol using oxytocin dilution of 10mU/mL, initial dose of 2mU/min (12mL/hr), and incrementalincrease of 2mU (12 mL) every 45 minutes until adequate contractions with the maximum dose being 16mU/min (96mL/ hr) [6]. Interpretation of intrapartum fetal heart rate pattern and uterine contractions was done according to ACOG guidelines [7,8]. Cases of uterine hyper-stimulation, antepartum hemorrhage, cases needed instrumental delivery or emergency Cesarean section, as well as neonates with apparent congenital anomalies at birth were all excluded (11 from group I and 16 from group II) and not involved in the analysis. The primary outcomes considered were Apgar score at 5th minute of birth and umbilical artery pH, while secondary outcomes were Apgar score at 1st minute of birth, umbilical artery pO2, pCO2 and base excess of all neonates.


Statistical Analysis

Statistical analysis was done on a personal computer using IBM® SPSS® Statistics version 19 (IBM® Corporation, Armonk, NY, USA). Kolmogorov-Smirnov test of normality was applied to all measured variables where quantitative variables were described as mean and standard deviation (SD), number and percentage, or median and inter-quartile range (IQR) as appropriate. The independent sample t-test was used to compare the two groups as regards quantitative variables in parametric data while Mann Whitney U test was used for non-parametric data and Chi square test was used for qualitative data. Relative risk and Odds ratio were used to calculate likelihood of negative effect with a confidence interval of 95%. Pearson’s correlation was used for measuring correlation between different variables. Significance level was always set at 0.05.


Result

Statistical analysis included 153 patients; 79 in Group I and 74 in Group II. Table 1 shows no significant difference between cases and controls regarding mean maternal age, BMI, gestational age, parity and mean cervical dilatation at enrollment (P>0.05).
Journal of Gynecology and Women’s Health
BMI body mass index [calculated as weight (kg) divided by squared height (m2)] Kg, Kilograms; m2, square meters; cm, centimeters. Analysis using independent student’s t-test or Mann Whitney U test as appropriate Data are presented as mean ± standard deviation or median (interquartile range, IQR) as appropriate.
Journal of Gynecology and Women’s Health
Analysis using independent student’s t-test, Chi square or Mann Whitney U test as appropriate Data are presented as median (interquartile range, IQR), number (%) or mean ± standard deviation as appropriate. ¶ Indicates statistical significance.

Table 2 illustrates studied neonatal outcomes showing no significant difference regarding neonatal weight, neonatal sex distribution, Apgar score at 1st and 5th minutes, as well as mean umbilical artery pCO2, pO2 and mean umbilical vein pH (P>0.05). However, umbilical artery base deficit was significantly more and pH was significantly less in case group (P=0.015; P=0.029; respectively).
Journal of Gynecology and Women’s Health
Interestingly, Figure 1 illustrates no significant difference between cases and controls regarding number of neonates with arterial pH less than 7.1 (13 (16.5%) versus 10 (13.5%); respectively) (RR=1.218, P=0.612; OR=1.261, P=0.611; 95%CI), while Figure 2 shows that number of neonates with significant impairment of arterial base deficit (>8mmol/L) didn’t show significant difference between cases and controls (16(20.3%) versus 11(14.9%); respectively) (RR=1.363, P=0.386; OR=1.455, P=0.384; 95%CI).
Journal of Gynecology and Women’s Health
Journal of Gynecology and Women’s Health
Journal of Gynecology and Women’s Health
In this study, Apgar scores at 1st and 5th minute were not correlated to any of maternal age, parity, gestational age, neonatal sex or neonatal weight. Also, umbilical artery pH and base excess have non-significant correlations to these variables (P>0.05; Table 3). Figure 3 illustrates Pearson’s correlation test between duration of oxytocin administration and umbilical artery pH among group I, showing a significant negative correlation (P<0.001).


Discussion

Although labor augmentation using oxytocin has been investigated in few trials, most of these trials have focused on various outcomes mainly duration of labor, rate of Cesarean sections or instrumental deliveries and maternal experience with few of them [9-11], have measured neonatal outcomes as a primary outcome. The current study reported that low-dose oxytocin use is associated with reduction of neonatal umbilical artery pH and increase in base deficit without compromising the neonatal clinical condition or affecting Apgar scores

Oxytocin transiently compromises fetal circulation by increasing duration, frequency and strength of uterine contractions where this effect was studied by Olofsson et al. [12], through ultrasound and Doppler assessment where uterine and umbilical artery flow resistance increased significantly during uterine contractions reflecting rapid and exaggerated increase of vascular resistance in both arteries.
The biochemical disturbance must be significant before Apgar score is affected [13]. Moreover, a number of factors may influence Apgar score, including trauma, drugs, infections, congenital anomalies, hypovolemia, hypoxia and preterm birth. Accordingly, it is inappropriate to use an Apgar score alone to establish the diagnosis of asphyxia [14].

In the year 2008, oxytocin was added to the list of medications designated as high alert by the Institute for Safe Medication, USA [15]; such drugs are defined as those bearing a heightened risk of harm when used in error. Not following the guidelines regarding use of oxytocin is probably one reason for adverse neonatal outcomes. The use of oxytocin is on the increase and it is estimated that about 50% of nulliparous and 20% of parous women receive oxytocin during delivery [16]. A recent Cochrane review by Kenyon et al. involved 4 randomized trials and found no significant difference for Apgar scores, umbilical cord blood gases, admission to special care baby unit, or neonatal mortality between cases managed by high-dose and those managed by lowdose oxytocin for labor augmentation [17].

The current study found no statistical difference neither in Apgar scores at 1st and 5th minutes nor in distribution of Apgar score values between both groups, where 5 neonates (6.3%) of the case group and 4 neonates (5.4%) of the control group had a score less than 7 at 1st minute while one neonate of each group had ascore less than 7 at 5th minute. No neonatal deaths were reported during the study. Three Neonates were diagnosed with TTN and no special care admissions occurred for any of the neonates involved.

These results are comparable to those of Chan and To, in their prospective study using low-dose oxytocin, who found that 6% of the neonates of the study group had Apgar scores less than 7 at one minute, while 100% of the neonates of their study group had Apgar scores more than 7 at 5 minutes [18]. Also, our results agree with Merrill and Zaltnik (3.9% of the studied neonates had Apgar score < 7 at 5 minutes) [19]. Melin et al. [20] have classified neonatal acidemia according to umbilical artery pH at birth as mild or pre-acidemia at 7.10 to 7.19, moderate acidemia at 7.00 to 7.09, and severe acidemia at pH less than 7.00. In a similar context, and for the purpose of prediction of the likelihood of neonatal encephalopathy, Low et al. [21] have classified neonatal acidosis, as regards umbilical arterial base deficits, as mild; 4–8 mmol/L, moderate; 8-12mmol/L, and severe acidosis; greater than 12mmol/L. Accordingly, in the current study, numbers of neonates with pH<7.1 and those with base deficits>8 mmol/ Litre, were comparable between both groups with no significant difference (OR=1.261 and 1.455; respectively), while, surprisingly, the case group showed a significantly lower arterial pH and a significantly higher arterial base deficit as compared to controls, which emphasizes the undeniable effect of oxytocin on the arterial acid-base status but this effect was not enough to increase the risk of developing neonatal academia, which agrees with Merrill and Zaltnik in their randomized double masked trial [19]. Also, Thorp et al. [10] conducted a study on 1423 primigravid women where 43% of them received high-dose oxytocin augmentation and no significant difference was noticed in mean arterial pH between oxytocin and no oxytocin groups. Contradictorily, Oscarsson et al. [16] in their massive retrospective study on 106,755 deliveries, concluded that oxytocin use increased the risk of low Apgar score at 5th minute and neonatal special care admission but their study remains limited by being retrospective and hence subject to recall bias as well as heterogeneity of population recruited from 10 different hospitals and not considering factors like uterine hyperstimulation.

In the current study, fifteen umbilical artery pH values (20.3%) of the control group were less than 7.2 which agrees with those of Akoury et al. [9] (20%) but they have used base deficit of 7mmol/L as a cut-off to diagnose neonatal acidosis and hence, 29% of cases and 27% of controls in their study were acidotic. Different modes of delivery might be another reason for different results.
The fact of occurrence of acidemia in non-augmented labors was explained by Yoon and Kim who concluded a normal significant fall in umbilical artery pH and bicarbonate with the presence of labor and increased duration of second stage of labor in healthy term neonates [22]. The current study hasn’t considered neonates with mild acidemia/acidosis as it is thought that mild acidosis occurs in almost all normal labors [23].

The current study uniquely reported the significant negative correlation between duration of oxytocin administration among the case group and umbilical artery pH which signifies the compromising effect of oxytocin on neonatal circulation studied by Olofsson et al. [12] and correlates with the duration of use not only the dose which has been studied in few trials. As oxytocin impairs the utero-placental and umbilical circulations, there might be a gradual accumulation of lactates or gradual affection of the fetal ability to compensate and wash lactates out of the circulation even in absence of uterine hyper-stimulation.

The limitation of this study is that it hasn’t studied the incidence of meconium staining at birth and risk of meconium aspiration as a neonatal outcome. Also, the progress of labor hasn’t been correlated with the results. Moreover, only low-dose oxytocin was studied and further studies are needed to evaluate effect of highdose oxytocin compared to controls and emphasize the effect of duration of oxytocin use on neonatal outcome with larger number of patients and correlate it to other neonatal parameters.  

 To know more about Gynecology and Women’s Health 
To know more about Juniper Publishers